Chicken Talin 1 (TLN1) ELISA Kit
Species Reactivity : Chicken (Gallus)
UniProt : P54939
Abbreviation : TLN1
Alternative Names : ILWEQ; KIAA1027; TLN;
Application : ELISA
Range : 0.625-40 ng/mL
Sensitivity : 0.216 ng/mL
Intra-AssayCV : ?5.2%
Inter-AssayCV : ?7.5%
Recovery : 0.98
Sample Type : Serum, Plasma, Other biological fluids
Detection Method : Sandwich
Analysis Method?? : Quantitive
Test principle : This assay employs a two-site sandwich ELISA to quantitate TLN1 in samples. An antibody specific for TLN1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyTLN1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conj µgated antibody specific for TLN1 is added to the wells. After washing, Streptavidin conj µgated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of TLN1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Product Overview : TALIN is a high-molec µLar-weight cytoskeletal protein concentrated at regions of cell-substratum contactand, in lymphocytes, at cell-cell contacts.Talin-1 is a cytoskeletal protein which is concentrated in areas of cell-substratum and cell-cell contacts. This protein plays a significant role in the assembly of actin filaments and in spreading and migration of various cell types, including fibroblasts and osteoclasts. It codistributes with integrins in the cell surface membrane in order to assist in the attachment of adherent cells to extracell µLar matrices and of lymphocytes to other cells. The N-terminus of this protein contains elements for localization to cell-extracell µLar matrix junctions. The C-terminus contains binding sites for proteins such as beta-1-integrin, actin, and vinc µLin.
Stability : The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calc µLated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C).